# GC/MS Analysis of Aromatics in Gasoline using ASTM D5769: Set-up, Optimization, and Automated Reporting

Separation Science, in collaboration with Agilent, offers an on-demand webinar describing best practices for setting up, optimizing, and running ASTM D5769 on a new, cost-effective GC/MS system. 

**Duration:** Approximately 60 minutes

**Presenters**  
![](https://webinar.sepscience.com/hs-fs/hubfs/Webinars/Agilent_280120/JimMcCurry.png?width=60&name=JimMcCurry.png)**Jim McCurry** is a senior applications chemist at Agilent specializing in analytical chemistry measurements for the chemical and refining industries. His current work is in multidimensional GC, trace analysis in complex matrices, and fast GC, and GC/MS.

![](https://webinar.sepscience.com/hs-fs/hubfs/Webinars/Agilent_280120/CraigMarvin.png?width=60&name=CraigMarvin.png)**Craig Marvin** serves as the Business and Product Marketing Manager for GC, MS and Sample Containment supplies within the Agilent CrossLab Group. His team collaborates with internal & external stakeholders to update existing and develop new technology for improving system performance for analyses across the market segments served by Agilent.

**Sponsor**  
![](https://webinar.sepscience.com/hs-fs/hubfs/Webinars/Agilent_090419/Agilent_Logo.png?width=200&name=Agilent_Logo.png)

[![Share on Facebook](https://static.hubspot.com/final/img/common/icons/social/facebook-24x24.png)](http://www.facebook.com/share.php?u=https%3A%2F%2Fwebinar.sepscience.com%2Fform%2Fgc%2Fms-analysis-of-aromatics-in-gasoline-using-astm-d5769%3Futm_medium%3Dsocial%26utm_source%3Dfacebook) [![Share on LinkedIn](https://static.hubspot.com/final/img/common/icons/social/linkedin-24x24.png)](http://www.linkedin.com/shareArticle?mini=true&url=https%3A%2F%2Fwebinar.sepscience.com%2Fform%2Fgc%2Fms-analysis-of-aromatics-in-gasoline-using-astm-d5769%3Futm_medium%3Dsocial%26utm_source%3Dlinkedin) [![Share on Twitter](https://static.hubspot.com/final/img/common/icons/social/twitter-24x24.png)](https://twitter.com/intent/tweet?original_referer=https%3A%2F%2Fwebinar.sepscience.com%2Fform%2Fgc%2Fms-analysis-of-aromatics-in-gasoline-using-astm-d5769%3Futm_medium%3Dsocial%26utm_source%3Dtwitter&url=https%3A%2F%2Fwebinar.sepscience.com%2Fform%2Fgc%2Fms-analysis-of-aromatics-in-gasoline-using-astm-d5769%3Futm_medium%3Dsocial%26utm_source%3Dtwitter&source=tweetbutton&text=GC%2FMS%20Analysis%20of%20Aromatics%20in%20Gasoline%20using%20ASTM%20D5769) [![Share on Email](https://static.hubspot.com/final/img/common/icons/social/email-24x24.png)](mailto:?subject=Check%20out%20https%3A%2F%2Fwebinar.sepscience.com%2Fform%2Fgc%2Fms-analysis-of-aromatics-in-gasoline-using-astm-d5769%3Futm_medium%3Dsocial%26utm_source%3Demail%20&body=Check%20out%20https%3A%2F%2Fwebinar.sepscience.com%2Fform%2Fgc%2Fms-analysis-of-aromatics-in-gasoline-using-astm-d5769%3Futm_medium%3Dsocial%26utm_source%3Demail)

## Register for this on-demand learning event ...

The unavailability of fluorescence dye has impacted the widely used D1319 method for determining total aromatics in reformulated gasoline. To remain in compliance with EPA regulations, many labs are considering the more complex D5769 GC/MS method for total aromatics analysis.

Successful performance of a GC/MS system depends on good chromatography, an inert flow path, and low background signal, where the quality of the carrier gas, whether achieved with filters or high-grade gas supply, and leak free connections play important roles in flow path and low backgrounds. Easy-to-use products for monitoring gas filter lifetime and installing columns help in the set-up and routine operation to increase the uptime of the GC/MS system.

This presentation offers best practices for setting up, optimizing, and running this method on a new, cost-effective GC/MS system. Data analysis approaches are also discussed with emphasis on a new system for automated reporting of results.

#### By viewing this presentation you will...

- Understand the different ASTM configurations and operations of D5769
- Learn techniques to optimize the Agilent 8860/5977 GC/MS system for running D5769
- Understand how the 8860/5877 GC/MS system performs for different D5769 configurations

To register for this on-demand webinar simply complete the form on the right. By clicking the 'View on-demand presentation' button, you submit your information to the webinar organizer, who as an independent content provider to analytical and laboratory scientists, will use it to communicate with you regarding this event and other similar platforms run in collaboration with other parties.

Registrants to this webinar are covered by the Eclipse Business Media [Privacy Policy](http://www.sepscience.com/privacy-policy).

Eclipse Business Media Ltd, Regd in England, No. 06513189, Woodview, Bull Lane Industrial Estate, Sudbury, CO10 0FD, United Kingdom, T +44 (0)161 818 7434, [info@sepscience.com](mailto:info@sepscience.com)

 

Eclipse Business Media Ltd needs the contact information you provide to us to contact you about our products and services. You may unsubscribe from these communications at any time. For information on how to unsubscribe, as well as our privacy practices and commitment to protecting your privacy, check out our [Privacy Policy](https://www.sepscience.com/privacy-policy/) or contact [privacy@labxmediagroup.com](mailto:privacy@labxmediagroup.com) 

Copyright © 2025. All rights reserved

[Contact Us](https://www.sepscience.com/contact-us/)  
[Advertise with Us](https://www.sepscience.com/advertise-with-us/)